top of page

HALTON / FLAMGARD
HIGH INTEGRITY HVAC DAMPERS

FLAMGARD LOGO_edited.jpg
Halton Wales Logo.jpg
image.png
image.png

Halton Wales MEI (Formerly Flamgard Calidair) – Marine & Energy Ventilation Solutions


Oceania Engineering Services is proud to represent Halton Wales MEI, formerly known as Flamgard Calidair, supporting their specialist ventilation and air movement solutions for marine and energy infrastructure applications across Australia and the region.
Halton Wales MEI has a long-standing reputation for delivering high-performance ventilation systems engineered for demanding offshore, marine and hazardous environments. Their product range includes bespoke ventilation packages, dampers and air movement solutions designed to meet stringent project and regulatory requirements within oil and gas, marine and energy facilities.


With a strong heritage in hazardous area and safety-critical ventilation systems, Halton Wales MEI solutions are developed to meet international standards and project-specific certification requirements. Their engineering-led approach ensures that each solution is designed to suit the operational, environmental and compliance constraints of the installation.
As the marine and energy infrastructure partner for Halton Wales MEI, OES provides local technical support, project coordination and integration expertise.

 

Combining Halton Wales MEI’s specialist ventilation engineering capability with OES’s offshore HVAC and hazardous area experience enables the delivery of robust, compliant and application-specific ventilation solutions for complex energy and marine environments.

Fire Dampers

Halton & Flamgard Fire Dampers for Demanding Applications

Fire dampers are used to prevent the spread of fire and smoke through the ventilation systems. In the event of a fire, the damper will automatically close, preventing the passage of flames and smoke through the ventilation ducts.

image.png

CFD-01 Fire Damper

(A0 (A60), H0(H120) or E120S and BS476 Fire Classifications)

Flamgard CFD-01 Fire damper. EN 1366-2 tested for categories ‘E’ Integrity ‘S’ Smoke . Maximum single module size 3100×3100 mm (DNV-GL), 2050×2050 mm (ABS) for A class applications. H class applications are also accommodated at various sizes.

  • Low leakage in accordance with EN 1751 Class 3 and Class C

  • ATEX rated

  • SIL 2 rated to IEC 62508-2:2010

  • NORSOK complaint

CFD-02 – Medium Duty Fire and Smoke Damper

Flamgard CFD-02 Fire and Smoke damper. The damper has been successfully tested in accordance for A Class installations by DNV Lloyds Register of Shipping, MED, USCG-EU MRA.

  • SIL 2 Rated to IEC 62508-2:2010

  • Low leakage in accordance to BS EN 1751 Class 3 and Class C

  • ATEX rated

  • NORSOK complaint

image_edited.png

FCE – Fire damper (EI 60 S)

Halton FCE fire dampers are CE-marked according EN 15650:2010 and tested according to EN 1366-2 standard. Halton FCE fire dampers are used as safety-related components in ventilation systems to prevent fire and smoke spreading through ducting.

  • Closed blade leakage to EN 1751,
    Class 3 size >=200×200 mm

  • Casing leakage to EN 1751, Class C

  • SIL 2 safety assessment certificate available for the damper on specific terms

  • Available as ATEX certified

FDB2 – A0(A60) Fire and Gas Damper

Halton FDB2 fire dampers are type-approved by the most recognized classification societies: class A0 without insulation, A15-A60 when suitably insulated. Blades contain silicone seals (effective up to 300 ºC) for low leakage in normal conditions and thermal expansion graphite seals (effective from 150 ºC) to increase tightness even up to 50% in a case of fire.

  • Closed blade leakage to EN 1751,

  • Class 1 to 3 depending on size

  • Casing leakage to EN 1751, Class B

  • SIL 2 safety assessment certificate available for the damper on specific terms

  • Available as ATEX certified by order

image_edited.png

FDO – A0(A60) Fire and Gas Damper

Halton FDO fire dampers are type-approved class A0 – A60 fire damper when suitably insulated. The blade contains seals (effective up to 270 ºC).

  • Closed blade leakage to EN 1751,
    Class 2 to 4 depending on size

  • Casing leakage to EN 1751, Class C

  • SIL 2 safety assessment certificate available for the damper on specific terms

  • Available as ATEX certified by order

image_edited.png

FDA – A0(A60) Fire and Gas Damper

Halton FDA fire dampers are type-approved by most recognized classification societies: A0 without insulation, A-15 to A-60 when suitably insulated. Blades contain stainless steel spring seals for low leakage in normal conditions and thermal expansion graphite seals (effective from 150ºC) to seal the damper in case of fire. Silicon sealing as an option.

  • Closed blade leakage to EN 1751,
    Class 3 for size > 300×300 mm and for size > 200×200 mm (silicon seals)

  • Casing leakage to EN 1751, Class C

  • SIL 2 safety assessment certificate available for the damper on specific terms

  • Available as ATEX certified by order

image_edited.png
image.png

FDH – H0(120) Fire and Gas Damper

Halton FDH fire dampers are type-approved by the most recognized classification societies: class H0(H120) fire damper when suitably insulated. Pre-insulated H0(H60) with ceramic wool at the factory. H0(H120) with additional insulation on site. Blades insulated with ceramic wool.

  • Closed blade leakage to EN 1751,
    Class 3 for size > 300×300 mm

  • Casing leakage to EN 1751, Class C

  • SIL 2 safety assessment certificate available for the damper on specific terms

  • Available as ATEX certified by order

​​​​​​​

Isolation Dampers

Halton & Flamgard Isolation and Retention Dampers for Demanding Applications

High integrity gas retention dampers are used for containing fire-extinguishing gases such as CO2 and FM200 within a ventilation or air-conditioning system during fire situations. They have a similar design to volume control dampers with additional seals to minimise leakage.

When actuated – electrical, pneumatic or hydraulic – gas retention dampers prevent movement of gases which are deployed to evacuate oxygen and effectively extinguish the fire, this assists the building systems – alarms, sprinklers etc. – and the fire authorities to ensure safe escape and to minimise fire damage.

CID-01 – Zero Leakage Isolation Damper

Flamgard type CID-01 Isolation Damper has been specifically designed to meet the tightest shut- off requirements of the industrial and nuclear markets, where isolation of ducting for filter replacement or duct inspection is required, without shutting down complete systems.

  • Total Isolation (case & blades) for pressures up to 50,000 Pa

  • ATEX rated

  • SIL 2 rated to IEC 62508-2:2010

image.png
No Image
Available

CID-02 – Single Blade Isolation Damper

Flamgard type CID-02 Isolation Damper has been designed to give maximum efficiency under arduous conditions and is suitable for fitting with the air flow in one direction only. The dampers may be installed vertically or horizontally.

  • SIL 2 rated to IEC 62508-2:2010

  • The range of isolation dampers incorporate various shut-off capabilities complying with EN 1751

  • ATEX rated

No Image
Available

CRD-01 – Gas Retention Damper

Flamgard type CRD-01 Inert Gas Retention Damper has been specifically designed for use as a high integrity Isolation Damper for Gas turbines and Power Generation applications where inert gasses at high pressure are utilized as extinguishants.

  • SIL 2 rated to IEC 62508-2:2010

  • ATEX rated

Blast Dampers

Halton & Flamgard Blast Dampers

Blast dampers are devices used to mitigate the effects of explosions or blasts in various industrial, commercial, and residential settings. They are designed to minimize damage to structures and equipment, protect personnel, and maintain the integrity of the building envelope during a blast event. Blast dampers work by absorbing, redirecting, or dissipating the energy generated by an explosion, thereby reducing the pressure and impulse caused by the blast. 

BLD-01 – High Pressure Blast Damper


Flamgard type BLD-01 High Pressure Blast Damper is of a high performance design suitable for the arduous conditions encountered in offshore/onshore oil and gas, marine, nuclear, tunnel and industrial environments. The Blast Damper has been independently blast performance tested and is certified by SIRA to 04ATEX9322 for ATEX Group II Category 2 G/D use by SIRA.

image.png
image.png

BLD-02 – Medium Pressure Blast Damper
 

Flamgard type BLD-02 Medium Pressure Blast Damper is of a high performance design suitable for the arduous conditions encountered in offshore/onshore oil and gas, marine, nuclear, tunnel and industrial environments. The Blast Damper has been independently blast performance tested and is certified bvy SIRA to 04ATEX9322 for ATEX Group II Category 2 G/D use by SIRA.

image_edited.png

BDH – Blast protection damper
 

Halton BDH blast dampers protect against overpressure in offshore, onshore and heavy industry ventilation systems. The BDH blast damper can be installed in rectangular ducts or wall openings. When the blades are in the open position, the device does not cause significant pressure loss, noise or flow disturbance.

PVKKS – Blast Valve


The PV-KK-S blast valve block comprises three spring balanced closing elements moving in a slot and closing the air passage against the valve seats in response to both positive and negative (suction) phase of the blast. The valve blocks are mounted in structural steel frames.

PVKKSX – Blast Valve


The PV-KK-SX blast valve block comprises three spring balanced closing elements moving in a slot and closing the air passage against the valve seats in response to both positive and negative (suction) phase of the blast. The valve blocks are mounted in stainless steel frames.

image_edited.png
image_edited.png

Volume Control Dampers

Halton & Flamgard Volume Control Dampers


Ducting systems must often provide a method of adjusting the volume of air flow to various parts of the system. High integrity volume control dampers (VCDs; not to be confused with smoke/fire dampers) provide this function. Besides the regulation provided at the registers or diffusers that spread air into individual rooms, dampers can be fitted within the ducts themselves.

 

These dampers may be manual or automatic. Zone dampers provide automatic control in simple systems while variable air volume (VAV) allows control in sophisticated systems.

No Image
Available

CCD-01 – Heavy Duty Control Damper


Flamgard type CCD-01 Heavy Duty Shut-Off and Control Damper has been specifically designed to meet the rigorous duty required in a hazardous environment where robust construction and dependable operation are of prime importance.

  • Can also be utilised as an High Integrity Isolation damper and/or Volume control damper

  • SIL 2 rated to IEC 62508-2:2010

  • ATEX rated

No Image
Available

CCD-02 – Medium Duty Control Damper


Flamgard CCD-02 Medium Duty Control Damper has been specifically designed for the industrial market where medium weight, construction and dependable operation are of prime importance. These versatile dampers are suitable for automatic and manual operation and may be used for: system balancing, pressure control, fresh air re circulation and many more functions.

  • Can also be utilised as an High Integrity Isolation damper and/or Volume control damper

  • SIL 2 rated to IEC 62508-2:2010

  • ATEX rated

UTP – Balancing damper


Halton UTP dampers are used to balance airflow rates in high pressure ductwork. Dampers meet international standards for rectangular and round ducts. In the open position, the blades face the direction of flow and do not cause a significant pressure loss.

  • Leakage class of a closed damper according to EN 1751:2014 class 1. Tested size 1000×1000 mm

  • Classification of casing leakage (EN 1751:2014) class B

image_edited.png

UTG – Gastight shut-off damper


Halton UTG dampers are used to shut-off and balance airflow rates in high pressure ductworks. Dampers meet international standards for rectangular and round ducts. In the open position, the blades face the direction of flow and do not cause a significant pressure loss. 

  • A closed damper fulfils the requirement of leakage class up to class 3 (EN1751:2014). Details available from Halton

  • Classification of casing leakage (EN 1751:2014) class B

image_edited.png
image_edited.png

UTA – Gastight shut-off damper


Halton UTA dampers are used to shut-off and balance airflow rates in high pressure ductworks. Dampers meet international standards for rectangular and round ducts. In the open position, the blades face the direction of flow and do not cause a significant pressure loss. The UTA is used as a shut-off, gas and balancing damper in applications where tightness and reliability are important.

  • A closed damper fulfils the requirement of leakage class 3 (EN1751:2014) for size ≥ 300×300 mm (stainless steel seals) and for size ≥ 150×150 mm (silicon seals)

  • Classification of casing leakage (EN1751:2014) class C

UTT – Multi-blade airflow management damper


Halton UTT dampers are used to shut off or control airflow in ductwork where tightness, thermal insulation and reliability are important.
In the closed position the Halton UTT damper leakage class is 3 in accordance with the EN1751 standard.

image_edited.png

Pressure Relief & Non-Return Dampers

Halton & Flamgard Pressure-Relief and Non-Return Dampers


Pressure dampers are used to control pressure levels in adjacent zones/areas. They are selected and installed to maintain a higher pressure than surrounding areas to prevent the ingress of hazardous gases. They are typically used in escape routes – fire fighting stairwells etc. – to assist in safe escape and to help the authorities deal with the emergency.

Backdraft dampers are used to prevent recirculation of ventilation air. Particularly useful as a low
cost solution to prevent air recirculation through an idle standby fan of a duty and standby ventilation fan configuration.

No Image
Available

CBD-01 – Heavy Duty Backdraught Damper


Flamgard type CBD-01 Backdraught Damper has been designed to give maximum efficiency under arduous conditions and is suitable for fitting with the air flow in one direction only.

  • SIL 2 rated to IEC 62508-2:2010

image.png

CBD-02 – Medium Duty to Low Leakage

Backdraught/Non Return Damper
Flamgard type CBD-02 Damper has been designed to give maximum shut-off under back-flow conditions and is suitable for fitting with the air flow in one direction only.

  • SIL 2 rated to IEC 62508-2:2010.

No Image
Available

CBD-02C – Circular Backdraught Damper


Flamgard type CBD-02C Circular Backdraught Damper has been designed to give maximum shut-off under back-flow conditions and is suitable for fitting with the air flow in one direction only.

No Image
Available

CPR01 – Pressure Relief Damper


Flamgard type CPR-01 Pressure Relief Damper has been designed to give maximum efficiency under arduous conditions and is suitable for the air outlets of electrical equipment rooms, control rooms and living quarters. These areas are maintained at a higher pressure than surrounding areas to prevent the ingress of hazardous gases. The differential pressure is usually 63 N/m² although this may be increased to provide a greater safety margin.

BLD – Non-Return Damper


Halton BLD non-return dampers are used in offshore and marine applications to prevent backflow through ventilation ductwork.

image_edited.png

BRD – Pressure-Relief Damper


Halton BRD pressure-relief dampers are used in offshore, marine and industrial applications to regulate the pressure in the ductwork system.

image_edited.png

Weather Louvres & Mist Eliminators

Halton & Flamgard Weather Louvres and Mist Eliminators also known as Droplet Separators


A weather louvre is a passive device, essentially a grille fixed over an opening, designed to let air through and keep water out. It is designed to the same standard as our other high integrity dampers and performs both these functions simultaneously. Its suitability for a particular application is determined by how effectively it achieves these functions in combination.

 

Droplet separators are used in heating, ventilation, and air conditioning (HVAC) systems to remove moisture droplets from air streams before they are distributed in a building, ship or used in industrial processes. This helps to maintain indoor air quality, prevent condensation, and protect HVAC components.

No Image
Available

CWL-01 – Fixed Blade Weather Louvre


Flamgard CWL-01 Fixed Blade Weather Louvre has been designed specifically to meet the arduous conditions encountered offshore and is suitable for fitting to duct inlets or exhausts.

No Image
Available

CWL-01C – Chevron Weather Louvre


Flamgard CWL-01C Chevron Weather Louvre is of a high performance design suitable for the arduous conditions encountered in marine environments. The louvre has been independently performance tested by BSRIA in accordance with the HEVAC standard weather louvre tests.

No Image
Available

HL – Triple Deflection Eliminator


Flamgard type HL high efficiency triple deflection moisture eliminator has been designed specifically to meet the arduous conditions encountered in offshore and marine environments and is suitable for fitting to duct inlets or exhausts where higher water removal rates can be achieved, than with conventional louvres.

No Image
Available

SL – Double Deflection Eliminator


Flamgard type SL high efficiency double deflection moisture eliminator has been designed specifically to meet the arduous conditions encountered in offshore and marine environments and is suitable for fitting to duct inlets or exhausts.

DSH – Highly Efficient Droplet Separator


Halton DSH high-efficiency droplet separators (water separator, mist eliminator) are designed for demanding applications such as marine, oil & gas, chemical, energy industries where reliability, easy installation and special design play an important role.

image_edited.png

DSA – Droplet Separator with Heating


Halton DSA high-efficiency droplet separators are designed for demanding applications such as oil & gas, chemical, energy and marine industries, where reliability, easy installation and special design play an important role. DSA droplet separators are fitted with heating elements. 

image_edited.png

Tunnel Dampers

Halton & Flamgard Tunnel Dampers


Flamgard Calidair’s tunnel dampers are rigidly designed and are used to regulate the airflow in transit tunnels. They ensure that the air that is circulating through the tunnel is safe for passenger transit, without excessive build up of exhaust gases. In normal conditions, tunnel dampers control the volumetric air flow in a transit tunnel.

In emergency fire conditions, it is essential that the dampers are there not only for ventilation, but to regulate the fire and the associated smoke and hot gases. Fires in tunnels generate severe smoke which, if not reliably ventilated, could cause those in the tunnel to suffer the life-threatening effects of smoke inhalation. Tunnel dampers can be used in emergency conditions to operate to extract these toxic fumes and smoke away from the critical area as well as providing a fire barrier when closed.

CFD-02TM – High temperature tunnel damper


Flamgard type CFD-02T High Temperature Tunnel Damper has been designed for bolting directly onto walls and floors or bolting or welding to steel support frames. The damper has been successfully tested and operated up to 400ºC for 2 hours. To ease installation these dampers can be supplied with pre-drilled flanges and mounting frames.

image.png
MARINE, ENERGY & OFFSHORE HVAC & REFRIGERATION SPECIALISTS – BRINGING TOGETHER INDUSTRY EXPERTS
Engineering | Equipment | Commissioning | Maintenance | Surveys | Assurance | Spare Parts | IECEx & ATEX
RGB_SCREEN_Single_Cert_ISO_9001_edited.png

AU006600-1

© 2025 by Oceania Engineering Services